Size: | |
---|---|
Availability: | |
Quantity: | |
XSA-V11801
KJT
KJT speed control switch products are mainly developed according to the actual needs of customer sites. The products have a wide range of electricity, and can be applied to 24VDC─110VAC─220VAC (different voltage levels are configured with intermediate relays of different voltages), bringing unified purchasing to users. Easy installation and good interchangeability. The product can effectively and timely handle electrical and process failures such as stalling, jamming, overloading, slow rotation, belt slipping, transmission chain (belt) falling off, transmission shaft breakage, etc. that often occur in motors and mechanical transmission devices. It can play a role in ensuring production and maintaining equipment.
AC/DC (slow type) | AC/DC (fast type) | |
Rated sensing distance (SN) | 10mm | 10mm |
Adjustable frequency range | 6-150 pulses/min | 120-3000 pulses/min |
2 lines | XVAV11801 | XSAV12801 |
characteristic | 2-wire formed cable | 2-wire formed cable |
Protection level | IP67 | IP67 |
Action range | 0-10mm | 0-10mm |
Detection accuracy | 3% of the actual detection distance Sr | 3% of the actual detection distance Sr |
operating temperature | -25 degrees-+70 degrees | -25 degrees-+70 degrees |
Rated voltage | 24-240V | 24-240V |
Voltage range (including ripple) | 20-254V | 20-254V |
Suitable for large switching frequencies | 6000 pulses/min | 48000 pulses/min |
Power-on delay | 9S+-20% | 9S+-20% |
KJT speed control switch products are mainly developed according to the actual needs of customer sites. The products have a wide range of electricity, and can be applied to 24VDC─110VAC─220VAC (different voltage levels are configured with intermediate relays of different voltages), bringing unified purchasing to users. Easy installation and good interchangeability. The product can effectively and timely handle electrical and process failures such as stalling, jamming, overloading, slow rotation, belt slipping, transmission chain (belt) falling off, transmission shaft breakage, etc. that often occur in motors and mechanical transmission devices. It can play a role in ensuring production and maintaining equipment.
AC/DC (slow type) | AC/DC (fast type) | |
Rated sensing distance (SN) | 10mm | 10mm |
Adjustable frequency range | 6-150 pulses/min | 120-3000 pulses/min |
2 lines | XVAV11801 | XSAV12801 |
characteristic | 2-wire formed cable | 2-wire formed cable |
Protection level | IP67 | IP67 |
Action range | 0-10mm | 0-10mm |
Detection accuracy | 3% of the actual detection distance Sr | 3% of the actual detection distance Sr |
operating temperature | -25 degrees-+70 degrees | -25 degrees-+70 degrees |
Rated voltage | 24-240V | 24-240V |
Voltage range (including ripple) | 20-254V | 20-254V |
Suitable for large switching frequencies | 6000 pulses/min | 48000 pulses/min |
Power-on delay | 9S+-20% | 9S+-20% |