This browser does not support the video element.
Directly replaces imported products of related models and has the following advantages:
■Low energy consumption (less than 15ma);
■1KHz---3KHz high-speed response;
■Automatic pin polarity protection, wiring errors will not damage the device itself;
■Pure copper silver-plated leads, long-term oxidation resistance, effectively ensuring system stability;
■Automatic load detection function, automatic protection and yellow light indication in case of short circuit or overload;
■Built-in amplifier and digital conversion circuit, unified output CMOS standard level, convenient signal collection, can be directly matched with a variety of loads;
■Action modes such as ON during light and ON during blackout can be switched by connecting the "L" terminal and the "+" terminal. This function can be used to easily form a suitable small control system;
Technical parameter | |
Model | ST Series (from ST670 to ST677) |
Sensing distance(all series) | 5mm (slot width) |
Standard detection object | Opaque object 2x0.8mm |
The difference distance | 0.025mm |
Output | NPN/PNP/NO/NC |
Light source (luminescencewave length) | GaAs infrared light-emitting diode (940nm) |
Indictor | The light turns on (red) when the light is blocked |
Power supply voltage | DC5V--DC24V+10%,ripple (p-p)less than 10% |
Static current consumption | 20mA or less (NPN type) |
KJT-ST676 control output | When receiving light, the indicator light is on, and the NPN collector has no output.when the light isblocked, the indicator light is off, and the NPN collector open circuit outputs DC5V-24V.below 100mA, and the residual voltageis below 0.5V (when the load current is 100mA). Residual voltage 0.3V or less (whenload current is 40mA) |
KJT-ST676 control output | The light indicator light remains on, and the NPN collector has no output; when therotor is blocked,the indicator light is on, and the NPN collector open circuit outputs DC5V--24V, below100mA, and the residual voltage is below0.5V (when the load current is 100mA). Residual voltage 0.3V or less (when the loadcurrent is 40mA) |
Automatic protection | Built-in polarity automatic protection circuit, the sensor itself will not be damaged when connected incorrectly, but it will not work |
Response frequency | 1KHz--3kHz |
Use environmentillumination | light-receiving surface illumination fluorescent lamp: 1000 1x or less |
Ambient temperature | During operation:25~ +55℃ during storage: -30 - +80℃ |
Ambient humidity | During operation:5~85%RH During storage: 5~ 95%RH |