There are many types of actuators, and they are designed with adjustable action positions. The shell is covered with reinforced plastic, waterproof and oil-proof. Type micro switch has higher mechanical strength and impact resistance. There are many categories of forward moving machines, and the action position is adjustable. The outer shell is covered in plastic, which is water- and oil-resistant and can withstand a beating.
model(azx) | 7100L | 7110L | 7310L | 7311L | 7312L | 7120L | 7140L | 7121L | 7141L | 7124L | 7144L | 7166L |
OF(max) | 600g | 600g | 600g | 600g | 600g | 150g | 220g | 180g | 240g | 200g | 280g | 120g |
RF(mix) | 100g | 100g | 100g | 100g | 100g | 40g | 60g | 50g | 80g | 60g | 100g | |
PT(max) | 2mm | 2mm | 2mm | 2mm | 2mm | 13.5mm | 8.5mm | 11mm | 6.5mm | 11mm | 6.5mm | 250mm |
OT(mix) | 0.8mm | 5mm | 6mm | 6mm | 6mm | 4mm | 2.5mm | 3mm | 2mm | 3mm | 2mm | 11mm |
MD(max) | 0.8mm | 0.8mm | 0.8mm | 0.8mm | 0.8mm | 3.2mm | 2mm | 2.4mm | 1.5mm | 2.4mm | 1.5mm | |
OP(mix) | 30.5±0.8mm | 44±1.2mm | 21.8±1.2mm | 33.3±1.2mm | 33.3±1.2mm | 25±1mm | 25±1mm | 40±1mm | 40±1mm | 50±1.2mm | 50±1.2mm | |
FP(mix) | 35mm | 32mm | 46mm | 56mm |
operating speed operating speed | 0.01 mm to 50 cm/sec (locking plug type), 0.01 mm to 50 cm/sec |
action frequency action frequency | 120 times/min, 120 times/min |
contact resistancecontact resistance | 15MΩ or less (initial), less than 15mΩ (initial) |
Insulation resistanceInsulation resistance | 100MΩ or more (below 500VDC), 100mΩ or more (below 500VDC) |
Withstand voltage bearing voltage | 1,000VAC, 50/60Hz for 1 minute between non-continuous terminals Between carrying and no-load current parts and between terminals and ground 1,500VAC, 50/60Hz for 1 minute Non-contact terminal: 1,000VAC, 50/60Hz for 1 minute One minute current and non-current parts and end and connection locations: 1,500VAC, 50/60Hz for one minute |
vibration | Malfunction endurance: 10 to 55Hz, 1.5mm double amplitude Action: 10 to 55Hz, 1.5mm pair swing |
impact | Mechanical durability: 1,000m/sec2 (about 100G, S) Malfunction durability: 300m/Sec2 (about 30G, S) Machine: 1,000m/Sec2 (about 100G Action: 300m/sec2 (about 30G ,S) |
ambient temperature | When in use: -10 to +80°C |
Humidity | Above 95% relative humidity, above 95% relative humidity |
service life | Mechanical: 10,000,000 times or more (at rated OT value) Electrical: 500,000 times or more Mechanical: 10,000,000 times or more (at rated OT) Electrical: more than 500,000 times |
weight | About 60g, about 60g |
Protection level | IEC specification: IP65, IEC specification: IP65 |